Archive for the ‘SCOM 2007 R2’ Category

Cannot initialize report.

The report server has encountered a configuration error. Logon failed for the unattended execution account (rsServerConfigurationError) (more…)

Loading reporting hierarchy failed

Symptoms

clip_image001

Root cause:

The report server cannot open a connection the the report server database

Workarround:

Reset password SQL Reporting Server uses to connect to the reports server database using script below

RSConfig.exe -c -s JKT-SCOM -d ReportServer -a Windows -u domain\admin.sqlscom -p password2010!!!

clip_image002

Result:

clip_image003

 

Source:

http://social.technet.microsoft.com/Forums/en-US/operationsmanagergeneral/thread/8a4e09d5-ea27-4491-b258-b0758ca77111

http://blogs.technet.com/b/randymonteleone/archive/2010/03/12/changing-password-on-scom-data-warehouse-run-as-accounts.aspx

Below are step by step to setup, create and delete the Report Scheduler on SCOM 2007 R2. By utilizing existing facilities, we do not need to create a report with the manual method. By using the Report This report will tergenerate Scheduler automatically, and (more…)